{"title":"Circuit Electrical System","description":"\u003cp\u003eA circuit electrical system is a structured network of electrical components interconnected to control and distribute electric power safely and efficiently. It typically consists of power sources (such as batteries or generators), conductors (wires or busbars), protective devices (circuit breakers, fuses), control elements (switches, relays), and loads (motors, lights, electronic devices).\u003c\/p\u003e\n\u003cp\u003eThe primary function of a circuit electrical system is to provide a controlled path for current flow, ensuring that electrical energy is delivered to the intended devices while minimizing risks such as overloads, short circuits, and electrical fires. Systems are designed according to voltage levels, load requirements, environmental conditions, and applicable safety standards (e.g., IEC, NEC, IEEE).\u003c\/p\u003e\n\u003cp\u003eIn modern applications, circuit electrical systems may incorporate smart monitoring, automation, and energy management features to optimize performance, improve reliability, and reduce energy consumption.\u003c\/p\u003e","products":[{"product_id":"fuel-filter-assembly-54-110-409-for-new-holland-tm120-tm130-tm140-tm155-tm175-tm190-case-mxm120-mxm130-mxm140-mxm155-mxm175-mxm190","title":"Fuel Filter Assembly 54\/110-409 for New Holland TM120 TM130 TM140 TM155 TM175 TM190 CASE MXM120 MXM130 MXM140 MXM155 MXM175 MXM190","description":"\u003cp\u003eFuel Filter Assembly 54\/110-409 for New Holland TM120 TM130 TM140 TM155 TM175 TM190 CASE MXM120 MXM130 MXM140 MXM155 MXM175 MXM190\u003c\/p\u003e\n\u003cp\u003ePart Number:54\/110-409, 54\/110409,87802726\u003c\/p\u003e\n\u003cp\u003eApplications:New Holland Tractor:TM120, TM130, TM140, TM155, TM175, TM190\u003c\/p\u003e\n\u003cp\u003eCASE-IH Tractor:MXM120, MXM130, MXM140, MXM155, MXM175, MXM190\u003c\/p\u003e","brand":"mechsc","offers":[{"title":"Default Title","offer_id":51782854443140,"sku":null,"price":50.0,"currency_code":"KRW","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/3839\/3476\/files\/955a3aaa-76da-4c64-96e5-ca15426b4e94.png?v=1780376943"},{"product_id":"12v-fuel-pump-416-5886-with-filter-416-5884-for-caterpillar-cat-loader-226d-232d-236d-239d-242d-246d-249d-257d-259d-262d-272d-277d-279d-287d-289d-297d-299d","title":"12V Fuel Pump 416-5886 with Filter 416-5884 for Caterpillar CAT Loader 226D 232D 236D 239D 242D 246D 249D 257D 259D 262D 272D 277D 279D 287D 289D 297D 299D","description":"\u003cp\u003e12V Fuel Pump 416-5886 with Filter 416-5884 for Caterpillar CAT Loader 226D 232D 236D 239D 242D 246D 249D 257D 259D 262D 272D 277D 279D 287D 289D 297D 299D\u003c\/p\u003e\n\u003cp\u003eReplace Part Number:\u003c\/p\u003e\n\u003cp\u003eElectric Fuel Pump:CA4165886, 416-5886, 4165886\u003c\/p\u003e\n\u003cp\u003eFuel Filter:CA4165884, 416-5884, 4165884\u003c\/p\u003e\n\u003cp\u003eApplications:\u003c\/p\u003e\n\u003cp\u003eFit For Caterpillar CAT Compact Track Loader:226D, 232D, 236D, 239D, 242D, 246D, 249D, 257D, 259D, 262D, 272D, 272D XHP, 272D2, 272D2 XHP, 277D, 279D, 287D, 289D, 297D, 297D XHP, 297D2, 297D2 XHP, 299D, 299D XHP, 299D2, 299D2 XHP\u003c\/p\u003e","brand":"mechsc","offers":[{"title":"Default Title","offer_id":51782887702660,"sku":null,"price":50.0,"currency_code":"KRW","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/3839\/3476\/files\/decea202-a700-42aa-9809-796cc75272b9.png?v=1777280019"},{"product_id":"vr6-automatic-voltage-regulator-avr-k65-12b-for-caterpillar-cat-generator","title":"VR6 Automatic Voltage Regulator AVR K65-12B for Caterpillar CAT Generator","description":"\u003cp\u003eVR6 Automatic Voltage Regulator AVR K65-12B for Caterpillar CAT Generator\u003c\/p\u003e\n\u003cp\u003ePart Number:K65-12B,K6512B\u003c\/p\u003e\n\u003cp\u003eApplications:For Caterpillar CAT Generator\u003c\/p\u003e\n\u003cp\u003eSpecification details:\u003c\/p\u003e\n\u003cp\u003ePower:SHUNT EXCITED\u003c\/p\u003e\n\u003cp\u003eInput:180-280 Vac,50\/60 Hz,1 OR 3-phase\u003c\/p\u003e\n\u003cp\u003ePMG EXCITED 63-105Vac 100\/240Hz 3-phase\u003c\/p\u003e\n\u003cp\u003eSensing input: 180-280Vac,50\/60Hz 1 or 3-phase\u003c\/p\u003e\n\u003cp\u003eCT input:1 or 5Aac 50\/60HzACC input:+\/- 3Vdc.Output:65Vdc@12Adc\u003c\/p\u003e\n\u003cp\u003eSpecification:\u003c\/p\u003e\n\u003cp\u003eK65-12BOutput power (with a 240 Vac Input):12 Adc @ 65 Vdc maximum continuous.25 Adc @ 125 Vdc forcing for 10 seconds.AC input power:100 to 280 Vac, single-phase 50 to 400 Hz, or 63 to 105 Vac;three phase,50 to 400 Hz, 1092 VA maximum continuous burdenAC sensing voltage:90 to 140 Vac, 50\/60 Hz; single- or three-phase.External voltage adjustrheostat:10k ohm, 2 W, potentiometerRegulation accuracy:±0.5% Average respondingVoltage drift:±1% voltage variation for a 40° C (104° F) change.Response time:\u0026lt; 4 millisecondsFrequency compensation:1 or 2 V\/Hz jumper selectable with knee adjustable from 45 Hz to 65 Hz.EMI suppression:Internal filterVoltage Build-Up:Internal provisions for automatic voltage build-up from generator residual voltages as low as six Vac.Over excitation shutdown:Over excitation protection starts timing at 90 Vdc ±5% and takes the output to zero in greater than 30 seconds. The output can be 125 Vdc for greater than 10 seconds.Droop1 Aor 5 A, \u0026lt;10 VA, adjustable from 0 to 10% at rated input current, 0.8 power factorUL recognized\/CSA certified:UL Recognized per Standard 508,UL File NO. E97035. CSA certifiedper Standard CAN\/CSA-C22.2 No.14-95, CSA File No. LR 23131\u003c\/p\u003e","brand":"mechsc","offers":[{"title":"Default Title","offer_id":51782888915076,"sku":null,"price":50.0,"currency_code":"KRW","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1002\/3839\/3476\/files\/7fe4d2d0-b5a7-4fc1-8b04-cfbfb2c4890f.png?v=1777273684"}],"url":"https:\/\/mechsc.com\/ja\/collections\/circuit-electrical-system.oembed","provider":"mechsc","version":"1.0","type":"link"}